@ -93,12 +93,19 @@ a bias velocity removed before thermostatting takes place; see the
|
||||
description below. The desired temperature at each timestep is a
|
||||
ramped value during the run from <I>Tstart</I> to <I>Tstop</I>. The <I>Tdamp</I>
|
||||
parameter is specified in time units and determines how rapidly the
|
||||
temperature is relaxed. For example, a value of 100.0 means to relax
|
||||
the temperature in a timespan of (roughly) 100 time units (tau or
|
||||
temperature is relaxed. For example, a value of 10.0 means to relax
|
||||
the temperature in a timespan of (roughly) 10 time units (e.g. tau or
|
||||
fmsec or psec - see the <A HREF = "units.html">units</A> command). The atoms in the
|
||||
fix group are the only ones whose velocities and positions are updated
|
||||
by the velocity/position update portion of the integration.
|
||||
</P>
|
||||
<P>IMPORTANT NOTE: A Nose-Hoover thermostat will not work well for
|
||||
arbitrary values of <I>Tdamp</I>. If <I>Tdamp</I> is too small, the temperature
|
||||
can fluctuate wildly; if it is too large, the temperature will take a
|
||||
very long time to equilibrate. A good choice for many models is a
|
||||
<I>Tdamp</I> of around 100 timesteps. Note that this is NOT the same as
|
||||
100 time units for most <A HREF = "units.html">units</A> settings.
|
||||
</P>
|
||||
<HR>
|
||||
|
||||
<P>The barostat for fix styles <I>npt</I> and <I>nph</I> is specified using one or
|
||||
@ -137,10 +144,17 @@ simulation box must be triclinic, even if its initial tilt factors are
|
||||
</P>
|
||||
<P>For all barostat keywords, the <I>Pdamp</I> parameter operates like the
|
||||
<I>Tdamp</I> parameter, determining the time scale on which pressure is
|
||||
relaxed. For example, a value of 1000.0 means to relax the pressure
|
||||
in a timespan of (roughly) 1000 time units (tau or fmsec or psec - see
|
||||
relaxed. For example, a value of 10.0 means to relax the pressure in
|
||||
a timespan of (roughly) 10 time units (e.g. tau or fmsec or psec - see
|
||||
the <A HREF = "units.html">units</A> command).
|
||||
</P>
|
||||
<P>IMPORTANT NOTE: A Nose-Hoover barostat will not work well for
|
||||
arbitrary values of <I>Pdamp</I>. If <I>Pdamp</I> is too small, the pressure
|
||||
and volume can fluctuate wildly; if it is too large, the pressure will
|
||||
take a very long time to equilibrate. A good choice for many models
|
||||
is a <I>Pdamp</I> of around 1000 timesteps. Note that this is NOT the same
|
||||
as 1000 time units for most <A HREF = "units.html">units</A> settings.
|
||||
</P>
|
||||
<P>Regardless of what atoms are in the fix group, a global pressure or
|
||||
stress tensor is computed for all atoms. Similarly, when the size of
|
||||
the simulation box is changed, all atoms are re-scaled to new
|
||||
|
||||
@ -85,12 +85,19 @@ a bias velocity removed before thermostatting takes place; see the
|
||||
description below. The desired temperature at each timestep is a
|
||||
ramped value during the run from {Tstart} to {Tstop}. The {Tdamp}
|
||||
parameter is specified in time units and determines how rapidly the
|
||||
temperature is relaxed. For example, a value of 100.0 means to relax
|
||||
the temperature in a timespan of (roughly) 100 time units (tau or
|
||||
temperature is relaxed. For example, a value of 10.0 means to relax
|
||||
the temperature in a timespan of (roughly) 10 time units (e.g. tau or
|
||||
fmsec or psec - see the "units"_units.html command). The atoms in the
|
||||
fix group are the only ones whose velocities and positions are updated
|
||||
by the velocity/position update portion of the integration.
|
||||
|
||||
IMPORTANT NOTE: A Nose-Hoover thermostat will not work well for
|
||||
arbitrary values of {Tdamp}. If {Tdamp} is too small, the temperature
|
||||
can fluctuate wildly; if it is too large, the temperature will take a
|
||||
very long time to equilibrate. A good choice for many models is a
|
||||
{Tdamp} of around 100 timesteps. Note that this is NOT the same as
|
||||
100 time units for most "units"_units.html settings.
|
||||
|
||||
:line
|
||||
|
||||
The barostat for fix styles {npt} and {nph} is specified using one or
|
||||
@ -129,10 +136,17 @@ simulation box must be triclinic, even if its initial tilt factors are
|
||||
|
||||
For all barostat keywords, the {Pdamp} parameter operates like the
|
||||
{Tdamp} parameter, determining the time scale on which pressure is
|
||||
relaxed. For example, a value of 1000.0 means to relax the pressure
|
||||
in a timespan of (roughly) 1000 time units (tau or fmsec or psec - see
|
||||
relaxed. For example, a value of 10.0 means to relax the pressure in
|
||||
a timespan of (roughly) 10 time units (e.g. tau or fmsec or psec - see
|
||||
the "units"_units.html command).
|
||||
|
||||
IMPORTANT NOTE: A Nose-Hoover barostat will not work well for
|
||||
arbitrary values of {Pdamp}. If {Pdamp} is too small, the pressure
|
||||
and volume can fluctuate wildly; if it is too large, the pressure will
|
||||
take a very long time to equilibrate. A good choice for many models
|
||||
is a {Pdamp} of around 1000 timesteps. Note that this is NOT the same
|
||||
as 1000 time units for most "units"_units.html settings.
|
||||
|
||||
Regardless of what atoms are in the fix group, a global pressure or
|
||||
stress tensor is computed for all atoms. Similarly, when the size of
|
||||
the simulation box is changed, all atoms are re-scaled to new
|
||||
|
||||
Reference in New Issue
Block a user