@ -395,44 +395,52 @@ Lost atoms ...
-------------- --------------
A simulation stopping with an error due to lost atoms can have multiple A simulation stopping with an error due to lost atoms can have multiple
causes. In the majority of cases, lost atoms are unexpected and a result causes. By default, LAMMPS checks for whether the total number of atoms
of extremely high velocities causing instabilities in the system, and is consistent with the sum of atoms "owned" by MPI processors every time
those velocities can result from a variety of issues. For ideas on how that thermodynamic output is written. In the majority of cases, lost
to track down issues with unexpected lost atoms, see :ref:`Fast moving atoms are unexpected and a result of extremely high velocities causing
atoms <hint05>` and :ref:`Neighbor list settings <hint09>` in the instabilities in the system, and those velocities can result from a
general troubleshooting section above. In specific situations however, variety of issues. For ideas on how to track down issues with
losing atoms is expected material behavior (e.g. with sputtering and unexpected lost atoms, see :ref:`Fast moving atoms <hint05>` and
surface evaporation simulations) and an unwanted crash can be resolved :ref:`Neighbor list settings <hint09>` in the general troubleshooting
by changing the :doc:`thermo_modify lost <thermo_modify>` keyword from section above. In specific situations however, losing atoms is expected
the default 'error' to 'warn' or 'ignore' (though heed the advice in material behavior (e.g. with sputtering and surface evaporation
:ref:`Ignoring lost atoms <hint06>` above!). simulations) and an unwanted crash can be resolved by changing the
:doc:`thermo_modify lost <thermo_modify>` keyword from the default
'error' to 'warn' or 'ignore' (though heed the advice in :ref:`Ignoring
lost atoms <hint06>` above!).
.. _err0009: .. _err0009:
Too many neighbor bins Too many neighbor bins
---------------------- ----------------------
The simulation box has become too large relative to the size of a The simulation box is or has become too large relative to the size of a
neighbor bin and LAMMPS is unable to store the needed number of neighbor bin (which in turn depends on the largest pair-wise cutoff by
bins. This typically implies the simulation box has expanded too far. default) and LAMMPS is unable to store the needed number of bins. This
This can happen when some atoms move rapidly apart with shrink-wrap boundaries typically implies the simulation box has expanded too far. That can
or when a fix (like fix deform or a barostat) excessively grows the simulation happen when some atoms move rapidly apart with shrink-wrap boundaries or
box. when a fix (like fix deform or a barostat) excessively grows the
simulation box. This can also happen, if the largest pair-wise cutoff
is small. In this case, the error can be avoided by using the
:doc:`neigh_modify command <neigh_modify>` to set the bin width to a
suitably large value.
.. _err0010: .. _err0010:
Unrecognized pair style ... is part of ... package which is not enabled in this LAMMPS binary Unrecognized ... style ... is part of ... package which is not enabled in this LAMMPS binary
--------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------------
The LAMMPS executable (binary) being used was not compiled with a package The LAMMPS executable (binary) being used was not compiled with a
containing the specified pair style. This indicates that the executable needs to package containing the specified style. This indicates that the
be re-built after enabling the correct package in the relevant Makefile or CMake executable needs to be re-built after enabling the correct package in
build directory. See :doc:`Section 3. Build LAMMPS <Build>` for more details. the relevant Makefile or CMake build directory. See
One can check if the expected package and pair style is present in the :doc:`Section 3. Build LAMMPS <Build>` for more details. One can check
executable by running it with the ``-help`` (or ``-h``) flag on the command if the expected package and pair style is present in the executable by
line. One common oversight, especially for beginner LAMMPS users, is to enable running it with the ``-help`` (or ``-h``) flag on the command line. One
the package, but to forget to run commands to rebuild (e.g., to run the final common oversight, especially for beginner LAMMPS users, is to enable the
``make`` or ``cmake`` command). package, but to forget to run commands to rebuild (e.g., to run the
final ``make`` or ``cmake`` command).
If this error is occurring with an executable that the user does not control If this error is occurring with an executable that the user does not control
(e.g., through a module on HPC clusters), the user will need to get in contact (e.g., through a module on HPC clusters), the user will need to get in contact
@ -770,9 +778,10 @@ with periodic boundaries or larger than the box with non-periodic
boundaries. It means that the positions and image flags have become boundaries. It means that the positions and image flags have become
inconsistent. LAMMPS will still compute bonded interactions based on inconsistent. LAMMPS will still compute bonded interactions based on
the closest periodic images of the atoms and thus in most cases the the closest periodic images of the atoms and thus in most cases the
results will be correct. Nevertheless, it is good practice to update results will be correct. However they can cause problems when such
the system so that the message does not appear. It will help with atoms are used with the fix rigid or replicate commands. Thus, it is
future manipulations of the system. good practice to update the system so that the message does not appear.
It will help with future manipulations of the system.
There is one case where this warning *must* appear: when you have a There is one case where this warning *must* appear: when you have a
chain of connected bonds that pass through the entire box and connect chain of connected bonds that pass through the entire box and connect