"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c :link(lws,http://lammps.sandia.gov) :link(ld,Manual.html) :link(lc,Section_commands.html#comm) :line angle_style hybrid command :h3 [Syntax:] angle_style hybrid style1 style2 ... :pre style1,style2 = list of one or more angle styles :ul [Examples:] angle_style hybrid harmonic cosine angle_coeff 1 harmonic 80.0 30.0 angle_coeff 2* cosine 50.0 :pre [Description:] The {hybrid} style enables the use of multiple angle styles in one simulation. An angle style is assigned to each angle type. For example, angles in a polymer flow (of angle type 1) could be computed with a {harmonic} potential and angles in the wall boundary (of angle type 2) could be computed with a {cosine} potential. The assignment of angle type to style is made via the "angle_coeff"_angle_coeff.html command or in the data file. In the angle_coeff commands, the name of an angle style must be added after the angle type, with the remaining coefficients being those appropriate to that style. In the example above, the 2 angle_coeff commands set angles of angle type 1 to be computed with a {harmonic} potential with coefficients 80.0, 30.0 for K, theta0. All other angle types (2-N) are computed with a {cosine} potential with coefficient 50.0 for K. If angle coefficients are specified in the data file read via the "read_data"_read_data.html command, then the same rule applies. E.g. "harmonic" or "cosine", must be added after the angle type, for each line in the "Angle Coeffs" section, e.g. Angle Coeffs :pre 1 harmonic 80.0 30.0 2 cosine 50.0 ... :pre If {class2} is one of the angle hybrid styles, the same rule holds for specifying additional BondBond (and BondAngle) coefficients either via the input script or in the data file. I.e. {class2} must be added to each line after the angle type. For lines in the BondBond (or BondAngle) section of the data file for angle types that are not {class2}, you must use an angle style of {skip} as a placeholder, e.g. BondBond Coeffs :pre 1 skip 2 class2 3.6512 1.0119 1.0119 ... :pre Note that it is not necessary to use the angle style {skip} in the input script, since BondBond (or BondAngle) coefficients need not be specified at all for angle types that are not {class2}. An angle style of {none} with no additional coefficients can be used in place of an angle style, either in a input script angle_coeff command or in the data file, if you desire to turn off interactions for specific angle types. :line [Restrictions:] This angle style can only be used if LAMMPS was built with the MOLECULAR package (which it is by default). See the "Making LAMMPS"_Section_start.html#start_3 section for more info on packages. Unlike other angle styles, the hybrid angle style does not store angle coefficient info for individual sub-styles in a "binary restart files"_restart.html. Thus when retarting a simulation from a restart file, you need to re-specify angle_coeff commands. [Related commands:] "angle_coeff"_angle_coeff.html [Default:] none