"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c :link(lws,http://lammps.sandia.gov) :link(ld,Manual.html) :link(lc,Section_commands.html#comm) :line thermo_modify command :h3 [Syntax:] thermo_modify keyword value ... :pre one or more keyword/value pairs may be listed :ulb,l keyword = {lost} or {norm} or {flush} or {line} or {format} or {temp} or {press} or {drot} or {grot} :l {lost} value = {error} or {warn} or {ignore} {norm} value = {yes} or {no} {flush} value = {yes} or {no} {line} value = {one} or {multi} {format} values = {int} string or {float} string or M string M = integer from 1 to N, where N = # of quantities being printed string = C-style format string {temp} value = compute ID that calculates a temperature {press} value = compute ID that calculates a pressure {drot} value = compute ID that calculates rotational energy for dipolar atoms {grot} value = compute ID that calculates rotational energy for granular atoms :pre :ule [Examples:] thermo_modify lost ignore flush yes thermo_modify temp myTemp format 3 %15.8g thermo_modify line multi format float %g :pre [Description:] Set options for how thermodynamic information is computed and printed by LAMMPS. IMPORTANT NOTE: These options apply to the currently defined thermo style. When you specify a "thermo_style"_thermo_style.html command, all thermodynamic settings are restored to their default values, including those previously set by a thermo_modify command. Thus if your input script specifies a thermo_style command, you should use the thermo_modify command after it. The {lost} keyword determines whether LAMMPS checks for lost atoms each time it computes thermodynamics and what it does if atoms are lost. If the value is {ignore}, LAMMPS does not check for lost atoms. If the value is {error} or {warn}, LAMMPS checks and either issues an error or warning. The code will exit with an error and continue with a warning. This can be a useful debugging option. The {norm} keyword determines whether the thermodynamic print-out is normalized by the number of atoms or is the total summed across all atoms. Different unit styles have different defaults for this setting. The {flush} keyword invokes a flush operation after thermodynamic info is written to the log file. This insures the output in that file is current (no buffering by the OS), even if LAMMPS halts before the simulation completes. The {line} keyword determines whether thermodynamics will be printed as a series of numeric values on one line or in a multi-line format with 3 quantities with text strings per line and a dashed-line header containing the timestep and CPU time. This modify option overrides the {one} and {multi} thermo_style settings. The {format} keyword sets the numeric format of individual printed quantities. The {int} and {float} keywords set the format for all integer or floating-point quantities printed. The setting with a numeric value (e.g. format 5 %10.4g) sets the format of the Mth value printed in each output line, the 5th column of output in this case. If the format for a specific column has been set, it will take precedent over the {int} or {float} setting. The {temp} keyword is used to determine how thermodynamic temperature is calculated, which is used by all thermo quantities that require a temperature ("temp", "press", "ke", "etotal", "enthalpy", "pxx", etc). The specified compute ID must have been previously defined by the user via the "compute"_compute.html command and it must be a style of compute that calculates a temperature. As described in the "thermo_style"_thermo_style.html command, thermo output uses a default compute for temperature with ID = {thermo_temp}. This option allows the user to override the default. The {press} keyword is used to determine how thermodynamic pressure is calculated, which is used by all thermo quantities that require a pressure ("press", "enthalpy", "pxx", etc). The specified compute ID must have been previously defined by the user via the "compute"_compute.html command and it must be a style of compute that calculates a pressure. As described in the "thermo_style"_thermo_style.html command, thermo output uses a default compute for pressure with ID = {thermo_press}. This option allows the user to override the default. The {drot} keyword is used to determine how rotational energy is calculated for dipolar atoms, which is used by the thermo_style keyword {drot}. The specified compute ID must have been previously defined by the user via the "compute"_compute.html command. As described in the "thermo_style"_thermo_style.html command, thermo output has a default compute for this calculation with ID = {thermo_rotate_dipole}. This option allows the user to override the default. The {grot} keyword is used to determine how rotational energy is calculated for granular atoms, which is used by the thermo_style keyword {grot}. The specified compute ID must have been previously defined by the user via the "compute"_compute.html command. As described in the "thermo_style"_thermo_style.html command, thermo output has a default compute for this calculation with ID = {thermo_rotate_gran}. This option allows the user to override the default. [Restrictions:] none [Related commands:] "thermo"_thermo.html, "thermo_style"_thermo_style.html [Default:] The option defaults are lost = error, norm = yes for unit style of {lj}, norm = no for unit style of {real} and {metal}, flush = no, temp/press/drot/grot = compute IDs defined by thermo_style. The defaults for the line and format options depend on the thermo style. For styles "one", "granular", and "custom" the line and format defaults are "one", "%8d", and "%12.8g". For style "multi", the line and format defaults are "multi", "%8d", and "%14.4f".