Files
lammps/examples/PACKAGES/electrode/graph-il/in.thermo
2022-11-27 23:46:00 +00:00

20 lines
785 B
Plaintext

# electrodes with thermopotentiostat
# for graphene-ionic liquid supercapacitor
boundary p p f # slab calculation
include settings.mod # styles, groups, computes and fixes
kspace_modify slab 3.0
unfix nvt # remove NVT thermostat included from "settings.mod"
fix conpthermo bot electrode/thermo -1.0 1.979 couple top 1.0 etypes on temp 500 100 7 symm on # temp tau rng
# to compare to regular constant potential, switch previous line to this:
#fix conp bot electrode/conp -1.0 1.979 couple top 1.0 etypes on symm on
fix nve electrolyte nve
# note ionic liquid does not reach 500K immediately
# because its thermal response time is finite
# run this about 10k steps (10ps) to reach preset temperature
thermo 50
thermo_style custom step temp c_ctemp epair etotal c_qbot c_qtop
run 500