"CFDEMproject Website"_lws - "Main Page"_main :c :link(lws,http://www.cfdem.com) :link(main,CFDEMcoupling_Manual.html) :line dataExchangeModel oneWayVTK command :h3 [Syntax:] Defined in "couplingProperties"_CFDEMcoupling_dicts.html#couplingProperties dictionary. dataExchangeModel oneWayVTK; oneWayVTKProps \{ DEMts timeStep; relativePath "path"; couplingFilename "filename"; maxNumberOfParticles number; \} :pre {timeStep} = time step size of stored DEM data :ulb,l {path} = path to the VTK data files relative do simulation directory :l {filename} = filename of the VTK file series :l {number} = maximum number of particles in DEM simulation :l :ule [Examples:] dataExchangeModel oneWayVTK; oneWayVTKProps \{ DEMts 0.0001; relativePath "../DEM/post"; couplingFilename "vtk_out%4.4d.vtk"; maxNumberOfParticles 30000; \} :pre [Description:] The data exchange model performs the data exchange between the DEM code and the CFD code. The {oneWayVTK} model is a model that can exchange particle properties from DEM to CFD based on previously stored VTK data. [Restrictions:] none [Related commands:] "dataExchangeModel"_dataExchangeModel.html