mirror of
https://github.com/ParticulateFlow/CFDEMcoupling-PFM.git
synced 2025-12-08 06:37:44 +00:00
47 lines
1.1 KiB
Plaintext
47 lines
1.1 KiB
Plaintext
"CFDEMproject Website"_lws - "Main Page"_main :c
|
|
|
|
:link(lws,http://www.cfdem.com)
|
|
:link(main,CFDEMcoupling_Manual.html)
|
|
|
|
:line
|
|
|
|
dataExchangeModel twoWayFiles command :h3
|
|
|
|
[Syntax:]
|
|
|
|
Defined in "couplingProperties"_CFDEMcoupling_dicts.html#couplingProperties
|
|
dictionary.
|
|
|
|
dataExchangeModel twoWayFiles;
|
|
twoWayFilesProps
|
|
\{
|
|
couplingFilename "filename";
|
|
maxNumberOfParticles number;
|
|
\}; :pre
|
|
|
|
{filename} = filename of the VTK file series :ulb,l
|
|
{number} = maximum number of particles in DEM simulation :l
|
|
:ule
|
|
|
|
[Examples:]
|
|
|
|
dataExchangeModel twoWayFiles;
|
|
twoWayFilesProps
|
|
\{
|
|
couplingFilename "vtk_out%4.4d.vtk";
|
|
maxNumberOfParticles 30000;
|
|
\} :pre
|
|
|
|
[Description:]
|
|
|
|
The data exchange model performs the data exchange between the DEM code and the CFD code. The twoWayFiles model is a model that can exchange particle properties from DEM to CFD and from CFD to DEM. Data is exchanged via files that are sequentially written/read by the codes.
|
|
|
|
[Restrictions:]
|
|
|
|
Developed only for two processors, one for DEM and one for CFD run.
|
|
|
|
[Related commands:]
|
|
|
|
"dataExchangeModel"_dataExchangeModel.html
|
|
|