Commit Graph

16 Commits

Author SHA1 Message Date
71dd72fef4 multicomponentFluid: Correct boundary conditions of non-solved species
Whilst the cell values of non-solved species do not change, the boundary
values might, and correcting them is necessary for certain
post-processing operations to produce sensible results.
2024-07-04 14:34:12 +01:00
cdafb7e42b multiphaseEuler: Prevent zero blending factors when alpha is zero 2024-06-18 08:11:58 +01:00
d444cb168d multiphaseEuler::phaseSystem::correctBoundaryFlux: Update the phase fluxes from the phase face-velocity and make relative
This update is necessary for mesh topology changes and mesh-to-mesh mapping
which update the phase face-velocity fields but not the fluxes.
2024-05-23 15:41:24 +01:00
476bb42b04 unitConversion: Unit conversions on all input parameters
The majority of input parameters now support automatic unit conversion.
Units are specified within square brackets, either before or after the
value. Primitive parameters (e.g., scalars, vectors, tensors, ...),
dimensioned types, fields, Function1-s and Function2-s all support unit
conversion in this way.

Unit conversion occurs on input only. OpenFOAM writes out all fields and
parameters in standard units. It is recommended to use '.orig' files in
the 0 directory to preserve user-readable input if those files are being
modified by pre-processing applications (e.g., setFields).

For example, to specify a volumetric flow rate inlet boundary in litres
per second [l/s], rather than metres-cubed per second [m^3/s], in 0/U:

    boundaryField
    {
        inlet
        {
            type            flowRateInletVelocity;
            volumetricFlowRate 0.1 [l/s];
            value           $internalField;
        }

        ...
    }

Or, to specify the pressure field in bar, in 0/p:

    internalField   uniform 1 [bar];

Or, to convert the parameters of an Arrhenius reaction rate from a
cm-mol-kcal unit system, in constant/chemistryProperties:

    reactions
    {
        methaneReaction
        {
            type    irreversibleArrhenius;
            reaction "CH4^0.2 + 2O2^1.3 = CO2 + 2H2O";
            A       6.7e12 [(mol/cm^3)^-0.5/s];
            beta    0;
            Ea      48.4 [kcal/mol];
        }
    }

Or, to define a time-varying outlet pressure using a CSV file in which
the pressure column is in mega-pascals [MPa], in 0/p:

    boundaryField
    {
        outlet
        {
            type            uniformFixedValue;
            value
            {
                type            table;
                format          csv;
                nHeaderLine     1;
                units           ([s] [MPa]); // <-- new units entry
                columns         (0 1);
                mergeSeparators no;
                file            "data/pressure.csv";
                outOfBounds     clamp;
                interpolationScheme linear;
            }
        }

        ...
    }

(Note also that a new 'columns' entry replaces the old 'refColumn' and
'componentColumns'. This is is considered to be more intuitive, and has
a consistent syntax with the new 'units' entry. 'columns' and
'componentColumns' have been retained for backwards compatibility and
will continue to work for the time being.)

Unit definitions can be added in the global or case controlDict files.
See UnitConversions in $WM_PROJECT_DIR/etc/controlDict for examples.
Currently available units include:

    Standard: kg m s K kmol A Cd

     Derived: Hz N Pa J W g um mm cm km l ml us ms min hr mol
              rpm bar atm kPa MPa cal kcal cSt cP % rad rot deg

A user-time unit is also provided if user-time is in operation. This
allows it to be specified locally whether a parameter relates to
real-time or to user-time. For example, to define a mass source that
ramps up from a given engine-time (in crank-angle-degrees [CAD]) over a
duration in real-time, in constant/fvModels:

    massSource1
    {
        type        massSource;
        points      ((1 2 3));
        massFlowRate
        {
            type        scale;
            scale       linearRamp;
            start       20 [CAD];
            duration    50 [ms];
            value       0.1 [g/s];
        }
    }

Specified units will be checked against the parameter's dimensions where
possible, and an error generated if they are not consistent. For the
dimensions to be available for this check, the code requires
modification, and work propagating this change across OpenFOAM is
ongoing. Unit conversions are still possible without these changes, but
the validity of such conversions will not be checked.

Units are no longer permitted in 'dimensions' entries in field files.
These 'dimensions' entries can now, instead, take the names of
dimensions. The names of the available dimensions are:

    Standard: mass length time temperature
              moles current luminousIntensity

     Derived: area volume rate velocity momentum acceleration density
              force energy power pressure kinematicPressure
              compressibility gasConstant specificHeatCapacity
              kinematicViscosity dynamicViscosity thermalConductivity
              volumetricFlux massFlux

So, for example, a 0/epsilon file might specify the dimensions as
follows:

    dimensions      [energy/mass/time];

And a 0/alphat file might have:

    dimensions      [thermalConductivity/specificHeatCapacity];

*** Development Notes ***

A unit conversion can construct trivially from a dimension set,
resulting in a "standard" unit with a conversion factor of one. This
means the functions which perform unit conversion on read can be
provided dimension sets or unit conversion objects interchangeably.

A basic `dict.lookup<vector>("Umean")` call will do unit conversion, but
it does not know the parameter's dimensions, so it cannot check the
validity of the supplied units. A corresponding lookup function has been
added in which the dimensions or units can be provided; in this case the
corresponding call would be `dict.lookup<vector>("Umean", dimVelocity)`.
This function enables additional checking and should be used wherever
possible.

Function1-s and Function2-s have had their constructors and selectors
changed so that dimensions/units must be specified by calling code. In
the case of Function1, two unit arguments must be given; one for the
x-axis and one for the value-axis. For Function2-s, three must be
provided.

In some cases, it is desirable (or at least established practice), that
a given non-standard unit be used in the absence of specific
user-defined units. Commonly this includes reading angles in degrees
(rather than radians) and reading times in user-time (rather than
real-time). The primitive lookup functions and Function1 and Function2
selectors both support specifying a non-standard default unit. For
example, `theta_ = dict.lookup<scalar>("theta", unitDegrees)` will read
an angle in degrees by default. If this is done within a model which
also supports writing then the write call must be modified accordingly
so that the data is also written out in degrees. Overloads of writeEntry
have been created for this purpose. In this case, the angle theta should
be written out with `writeEntry(os, "theta", unitDegrees, theta_)`.
Function1-s and Function2-s behave similarly, but with greater numbers
of dimensions/units arguments as before.

The non-standard user-time unit can be accessed by a `userUnits()`
method that has been added to Time. Use of this user-time unit in the
construction of Function1-s should prevent the need for explicit
user-time conversion in boundary conditions and sub-models and similar.

Some models might contain non-typed stream-based lookups of the form
`dict.lookup("p0") >> p0_` (e.g., in a re-read method), or
`Umean_(dict.lookup("Umean"))` (e.g., in an initialiser list). These
calls cannot facilitate unit conversion and are therefore discouraged.
They should be replaced with
`p0_ = dict.lookup<scalar>("p0", dimPressure)` and
`Umean_(dict.lookup<vector>("Umean", dimVelocity))` and similar whenever
they are found.
2024-05-16 09:01:46 +01:00
cdef200385 MRF: Make flux relative following correctPhi
This fixes an incompatibility between MRF and adaptive mesh refinement
2024-05-07 14:45:21 +01:00
b4b98c1e35 multiphaseEuler: Corrected file names in model construction error messages 2024-02-09 12:13:55 +00:00
2f724bdc91 multiphaseEuler::phaseModel: Changed the phase-fraction field construction to work around a problem with Clang
The Clang compiler does not use std::move to transfer the result of the ternary
operator into the phase-fraction field resulting in it not being registered to
the database.  To work around this limitation/bug the ternary operator is now
provided with tmp fields the result of which is passed with an IOobject to the
final field constructor to ensure it is registered and the IO options set
correctly.
2024-01-12 15:18:07 +00:00
d5df0a96f1 populationBalance: Allocation coefficient bounds handling
An enumeration has been added to the arguments of the allocation
coefficient function, eta, to allow specification of how to allocate out
of bounds of the population balance size-groups. There are two options:

- "Clamp" will create an out-of-bounds allocation coefficient of exactly
  one. This partitions unity across all size-space.

- "Extrapolate" will create an out-of-bounds allocation coefficient in
  proportion to the ratio between the given size and the nearest
  size-group size. This does not partition unity outside the range of
  the size-groups.

The previous operation is equivalent to "Extrapolate".

It is not yet clear which method is preferable and under what
circumstances. More testing is required. The enumeration has been
created to facilitate this testing.
2023-12-15 10:05:43 +00:00
5ab61c60de basicThermo: Make molar mass available to basic thermos 2023-12-01 16:54:08 +00:00
f6f55caf02 Removed "<modelType>Type type" tautology in selection error messages 2023-11-28 16:40:42 +00:00
0ed84ff137 compressibleVoF,multiphaseEuler: Renamed compressibility dilatation dgdt to vDot
Currently in compressibleVoF vDot contains only the compressibility dilatation
effect whereas in multiphaseEuler the effect of sources are also included but
this will be refactored shortly so that the handling of mass sources and
compressibility is consistent between VoF and Euler-Euler solvers.

The previously hard-coded 1e-4 division stabilisation used when linearising vDot
for bounded semi-implicit solution of the phase-fractions is now an optional
user-input with keyword vDotResidualAlpha, e.g. in multiphaseEuler:

solvers
{
    "alpha.*"
    {
        nAlphaCorr          1;
        nAlphaSubCycles     2;
        vDotResidualAlpha   1e-6;
    }
    .
    .
    .
2023-11-03 13:19:52 +00:00
6dc6d3d089 phaseSystem::correctKinematics:: Ensure pressure is requested only for moving phase
The pressure field is not available from stationary solid phases.
2023-10-16 19:41:39 +01:00
ad3d25dc30 multiphaseEuler::IsothermalSolidPhaseModel: New phase model for isothermal stationary solid phases
IsothermalSolidPhaseModel does not update energy and density from pressure
whereas IsothermalPhaseModel does to allow compressible fluid phases to change
volume due to pressure changes.
2023-10-12 16:24:31 +01:00
5e03874bbb multiphaseEuler: Updated to us the new phaseSolidThermophysicalTransportModel class
for thermophysical transport within stationary solid phases.  This provides a
consistent interface to heat transport within solids for single and now
multiphase solvers so that for example the wallHeatFlux functionObject can now
be used with multiphaseEuler, see tutorials/multiphaseEuler/boilingBed.
Also this development supports anisotropic thermal conductivity within the
stationary solid regions which was not possible previously.

The tutorials/multiphaseEuler/bed and tutorials/multiphaseEuler/boilingBed
tutorial cases have been updated for phaseSolidThermophysicalTransportModel by
changing the thermo type in physicalProperties.solid to heSolidThermo.  This
change will need to be made to all multiphaseEuler cases involving stationary
phases.
2023-10-11 14:53:09 +01:00
da442e8eab multiphaseEuler: Replaced pPrime() with pPrimef()
to provide greater flexibility in the treatment of the face pPrime for particle
phase pressure models.
2023-09-22 16:16:49 +01:00
597121a4a7 multiphaseEuler: Library reorganisation
This change makes multiphaseEuler more consistent with other modules and
makes its sub-libraries less inter-dependent. Some left-over references
to multiphaseEulerFoam have also been removed.
2023-09-15 14:45:26 +01:00