Commit Graph

2 Commits

Author SHA1 Message Date
171101d1e5 fvModels: Specify source property values in field files
When an fvModel source introduces fluid into a simulation it should also
create a corresponding source term for all properties transported into
the domain by that injection. The source is, effectively, an alternative
form of inlet boundary, on which all transported properties need an
inlet value specified.

These values are now specified in the property field files. The
following is an example of a 0/U file in which the velocity of fluid
introduced by a fvModel source called "injection1" is set to a fixed
value of (-1 0 0):

    dimensions      [0 1 -1 0 0 0 0];

    internalField   uniform (0 0 0);

    boundaryField
    {
        #includeEtc "caseDicts/setConstraintTypes"

        wall
        {
            type            noSlip;
        }

        atmosphere
        {
            type            pressureInletOutletVelocity;
            value           $internalField;
        }
    }

    // *** NEW ***
    sources
    {
        injection1
        {
            type            uniformFixedValue;
            uniformValue    (-1 0 0);
        }
    }

And the following entry in the 0/k file specifies the turbulent kinetic
energy introduced as a fraction of the mean flow kinetic energy:

    sources
    {
        injection1
        {
            type            turbulentIntensityKineticEnergy;
            intensity       0.05;
        }
    }

The specification is directly analogous to boundary conditions. The
conditions are run-time selectable and can be concisely implemented.
They can access each other and be inter-dependent (e.g., the above,
where turbulent kinetic energy depends on velocity). The syntax keeps
field data localised and makes the source model (e.g., massSource,
volumeSource, ...) specification independent from what other models and
fields are present in the simulation. The 'fieldValues' entry previously
required by source models is now no longer required.

If source values need specifying and no source condition has been
supplied in the relevant field file then an error will be generated.
This error is similar to that generated for missing boundary conditions.
This replaces the behaviour where sources such as these would introduce
a value of zero, either silently or with a warning. This is now
considered unacceptable. Zero might be a tolerable default for certain
fields (U, k), but is wholly inappropriate for others (T, epsilon, rho).

This change additionally makes it possible to inject fluid into a
multicomponent solver with a specified temperature. Previously, it was
not possible to do this as there was no means of evaluating the energy
of fluid with the injected composition.
2023-10-12 11:24:27 +01:00
9181a699f2 fvModels: Added volumeSource model
This fvModel applies a volume source to the continuity equation and to
all field equations. It can be applied to incompressible solvers, such
as incompressibleFluid and incompressibleVoF. For compressible solvers,
use the massSource model instead.

If the volumetric flow rate is positive then user-supplied fixed
property values are introduced to the field equations. If the volumetric
flow rate is negative then properties are removed at their current
value.

Example usage:

    volumeSource
    {
        type            volumeSource;

        select          cellSet;
        cellSet         volumeSource;

        volumetricFlowRate 1e-4;

        fieldValues
        {
            U               (10 0 0);
            k               0.375;
            epsilon         14.855;
        }
    }

If the volumetric flow rate is positive then values should be provided
for all solved for fields. Warnings will be issued if values are not
provided for fields for which transport equations are solved. Warnings
will also be issued if values are provided for fields which are not
solved for.
2023-09-28 09:04:36 +01:00