Author SHA1 Message Date
fdbf3c134f Rationalized dictionary and configuration file headers 2018-07-09 15:40:05 +01:00
bf54ab67e1 Updated OpenFOAM Foundation web-link in headers 2018-07-06 21:42:54 +01:00
82675f0976 Merged reactingParcelFilmFoam into reactingParcelFoam
The combined solver includes the most advanced and general functionality from
each solver including:

    Continuous phase
    Lagrangian multiphase parcels
    Optional film
    Continuous and Lagrangian phase reactions
    Radiation
    Strong buoyancy force support by solving for p_rgh

The reactingParcelFoam and reactingParcelFilmFoam tutorials have been combined
and updated.
2017-08-29 09:33:45 +01:00
07ae9b67cc totalPressureFvPatchScalarField, uniformTotalPressureFvPatchScalarField: simplified and rationalized
The modes of operation are set by the dimensions of the pressure field
    to which this boundary condition is applied, the \c psi entry and the value
    of \c gamma:
    \table
        Mode                    | dimensions | psi   | gamma
        incompressible subsonic | p/rho      |       |
        compressible subsonic   | p          | none  |
        compressible transonic  | p          | psi   | 1
        compressible supersonic | p          | psi   | > 1
    \endtable

    For most applications the totalPressure boundary condition now only
    requires p0 to be specified e.g.
    outlet
    {
        type            totalPressure;
        p0              uniform 1e5;
    }
2016-06-16 12:21:34 +01:00
e22c65dd8e Standardized the selection of required and optional fields in BCs, fvOptions, functionObjects etc.
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry.  Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':

        Property     | Description             | Required    | Default value
        U            | velocity field name     | no          | U
        phi          | flux field name         | no          | phi
        .
        .
        .

However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.

        Property     | Description             | Required    | Default value
        pName        | pressure field name     | no          | p
        UName        | velocity field name     | no          | U

This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance.  In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.
2016-05-21 20:28:20 +01:00
6043a0f3a8 reactingParcelFoam, coalChemistryFoam: Added LTS support
Replaces LTSReactingParcelFoam and LTSCoalChemistryFoam

    Select LTS via the ddtScheme:

        ddtSchemes
        {
            default         localEuler rDeltaT;
        }
2015-06-28 11:01:04 +01:00