The standard Jayatilleke thermal wall function now permits evaluation
via static functions. The boiling wall function now uses these
functions, thereby removing the phase-Jayatilleke base class and
associated duplication of the Jayatilleke model.
This serves as an example of cavitation modelling with the
multiphaseEuler module. This case also contains validation of the
pressure profile along the hydrofoil against experimental data.
Based on a case contributed by Petteri Peltonen, VTT.