Files
OpenFOAM-12/tutorials/compressible/rhoPorousSimpleFoam/angledDuctImplicit/constant/fvOptions
Henry Weller e3c67dc111 fvOptions: The "<type>Coeffs" sub-dictionary is now optional
For example the actuationDiskSource fvOption may now be specified

disk1
{
    type            actuationDiskSource;

    fields      (U);

    selectionMode   cellSet;
    cellSet         actuationDisk1;
    diskDir         (1 0 0);    // Orientation of the disk
    Cp              0.386;
    Ct              0.58;
    diskArea        40;
    upstreamPoint   (581849 4785810 1065);
}

rather than

disk1
{
    type            actuationDiskSource;
    active          on;

    actuationDiskSourceCoeffs
    {
        fields      (U);

        selectionMode   cellSet;
        cellSet         actuationDisk1;
        diskDir         (1 0 0);    // Orientation of the disk
        Cp              0.386;
        Ct              0.58;
        diskArea        40;
        upstreamPoint   (581849 4785810 1065);
    }
}

but this form is supported for backward compatibility.
2017-04-13 13:30:17 +01:00

31 lines
1.0 KiB
C++

/*--------------------------------*- C++ -*----------------------------------*\
| ========= | |
| \\ / F ield | OpenFOAM: The Open Source CFD Toolbox |
| \\ / O peration | Version: dev |
| \\ / A nd | Web: www.OpenFOAM.org |
| \\/ M anipulation | |
\*---------------------------------------------------------------------------*/
FoamFile
{
version 2.0;
format ascii;
class dictionary;
location "constant";
object fvOptions;
}
// * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * //
source1
{
type fixedTemperatureConstraint;
selectionMode cellZone;
cellZone porosity;
mode uniform;
temperature 350;
}
// ************************************************************************* //