Commit Graph

4 Commits

Author SHA1 Message Date
07ae9b67cc totalPressureFvPatchScalarField, uniformTotalPressureFvPatchScalarField: simplified and rationalized
The modes of operation are set by the dimensions of the pressure field
    to which this boundary condition is applied, the \c psi entry and the value
    of \c gamma:
    \table
        Mode                    | dimensions | psi   | gamma
        incompressible subsonic | p/rho      |       |
        compressible subsonic   | p          | none  |
        compressible transonic  | p          | psi   | 1
        compressible supersonic | p          | psi   | > 1
    \endtable

    For most applications the totalPressure boundary condition now only
    requires p0 to be specified e.g.
    outlet
    {
        type            totalPressure;
        p0              uniform 1e5;
    }
2016-06-16 12:21:34 +01:00
e22c65dd8e Standardized the selection of required and optional fields in BCs, fvOptions, functionObjects etc.
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry.  Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':

        Property     | Description             | Required    | Default value
        U            | velocity field name     | no          | U
        phi          | flux field name         | no          | phi
        .
        .
        .

However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.

        Property     | Description             | Required    | Default value
        pName        | pressure field name     | no          | p
        UName        | velocity field name     | no          | U

This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance.  In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.
2016-05-21 20:28:20 +01:00
0ae18335f6 tutorials/compressible/sonicDyMFoam/movingCone: sonic version of the pimpleDyMFoam/movingCone tutorial 2015-02-22 16:53:33 +00:00
446e5777f0 Add the OpenFOAM source tree 2014-12-10 22:40:10 +00:00