Files
OpenFOAM-5.x/tutorials/incompressible
Henry Weller 07ae9b67cc totalPressureFvPatchScalarField, uniformTotalPressureFvPatchScalarField: simplified and rationalized
The modes of operation are set by the dimensions of the pressure field
    to which this boundary condition is applied, the \c psi entry and the value
    of \c gamma:
    \table
        Mode                    | dimensions | psi   | gamma
        incompressible subsonic | p/rho      |       |
        compressible subsonic   | p          | none  |
        compressible transonic  | p          | psi   | 1
        compressible supersonic | p          | psi   | > 1
    \endtable

    For most applications the totalPressure boundary condition now only
    requires p0 to be specified e.g.
    outlet
    {
        type            totalPressure;
        p0              uniform 1e5;
    }
2016-06-16 12:21:34 +01:00
..