Commit Graph

31 Commits

Author SHA1 Message Date
bf52a98e09 tutorials::Allrun: getApplication -> $(getApplication) 2018-05-28 22:20:07 +01:00
9221dd0d0f tutorials: Removed 0.orig directories in favor of <field>.orig
The new automated <field>.orig reading has made 0.orig directories and
associated scripting redundant.
2018-02-15 20:14:27 +00:00
df6e2da2dd OpenFOAM field reading: Automated the handling of <field>.orig files
Now if a <field> file does not exist first the compressed <field>.gz file is
searched for and if that also does not exist the <field>.orig file is searched
for.

This simplifies case setup and run scripts as now setField for example can read
the <field>.orig file directly and generate the <field> file from it which is
then read by the solver.  Additionally the cleanCase function used by
foamCleanCase and the Allclean scripts automatically removed <field> files if
there is a corresponding <field>.orig file.  So now there is no need for the
Allrun scripts to copy <field>.orig files into <field> or for the Allclean
scripts to explicitly remove them.
2018-02-14 17:42:14 +00:00
0248dd81e3 Corrected comments: inbetween -> in between 2018-02-13 16:38:41 +00:00
d2175f8fe0 fvOptions: verticalDamping: Added spatial ramping
The onset of vertical damping can now be graduated over a distance. The
user specifies an origin and a direction along which the graduation
occurs, and a ramping function to specify the form of the graduation. An
example specification for the fvOption is:

    verticalDamping1
    {
        type            verticalDamping;

        selectionMode   all;

        origin          (1200 0 0);
        direction       (1 0 0);
        ramp
        {
            type        halfCosineRamp;
            start       0;
            duration    600;
        }

        lambda          [0 0 -1 0 0 0 0] 1; // Damping coefficient

        timeStart       0;
        duration        1e6;
    }

If the origin, direction or ramp entries are omitted then the fvOption
functions as before; applying the damping to the entire volume or the
specified cell set.

This work was supported by Jan Kaufmann and Jan Oberhagemann at DNV GL.
2018-01-09 08:47:37 +00:00
8b44230384 MRF tutorials: Change rotor velocity boundary condition to fixedValue
Using the noSlip boundary condition for rotating wall in an MRF region
interferes with post-processing by resetting the wall velocity to 0 rather than
preserving the value set by the MRF zone.
2018-01-05 15:13:46 +00:00
46704f121b interFoam: Merged dynamic mesh functionality of interDyMFoam into interFoam
and replaced interDyMFoam with a script which reports this change.

The interDyMFoam tutorials have been moved into the interFoam directory.

This change is one of a set of developments to merge dynamic mesh functionality
into the standard solvers to improve consistency, usability, flexibility and
maintainability of these solvers.

Henry G. Weller
CFD Direct Ltd.
2017-11-30 23:56:42 +00:00
30602652da tutorials/multiphase/interFoam/laminar/wave: Consistency updates 2017-09-08 14:58:18 +01:00
2aa78c6db3 tutorials: interFoam: Added 2D wave propagation case 2017-05-31 10:09:14 +01:00
9801c25788 The "<type>Coeffs" sub-dictionary is now optional for most model parameters
except turbulence and lagrangian which will also be updated shortly.

For example in the nonNewtonianIcoFoam offsetCylinder tutorial the viscosity
model coefficients may be specified in the corresponding "<type>Coeffs"
sub-dictionary:

transportModel  CrossPowerLaw;

CrossPowerLawCoeffs
{
    nu0         [0 2 -1 0 0 0 0]  0.01;
    nuInf       [0 2 -1 0 0 0 0]  10;
    m           [0 0 1 0 0 0 0]   0.4;
    n           [0 0 0 0 0 0 0]   3;
}

BirdCarreauCoeffs
{
    nu0         [0 2 -1 0 0 0 0]  1e-06;
    nuInf       [0 2 -1 0 0 0 0]  1e-06;
    k           [0 0 1 0 0 0 0]   0;
    n           [0 0 0 0 0 0 0]   1;
}

which allows a quick change between models, or using the simpler

transportModel  CrossPowerLaw;

nu0         [0 2 -1 0 0 0 0]  0.01;
nuInf       [0 2 -1 0 0 0 0]  10;
m           [0 0 1 0 0 0 0]   0.4;
n           [0 0 0 0 0 0 0]   3;

if quick switching between models is not required.

To support this more convenient parameter specification the inconsistent
specification of seedSampleSet in the streamLine and wallBoundedStreamLine
functionObjects had to be corrected from

    // Seeding method.
    seedSampleSet   uniform;  //cloud; //triSurfaceMeshPointSet;

    uniformCoeffs
    {
        type        uniform;
        axis        x;  //distance;

        // Note: tracks slightly offset so as not to be on a face
        start       (-1.001 -0.05 0.0011);
        end         (-1.001 -0.05 1.0011);
        nPoints     20;
    }

to the simpler

    // Seeding method.
    seedSampleSet
    {
        type        uniform;
        axis        x;  //distance;

        // Note: tracks slightly offset so as not to be on a face
        start       (-1.001 -0.05 0.0011);
        end         (-1.001 -0.05 1.0011);
        nPoints     20;
    }

which also support the "<type>Coeffs" form

    // Seeding method.
    seedSampleSet
    {
        type        uniform;

        uniformCoeffs
        {
            axis        x;  //distance;

            // Note: tracks slightly offset so as not to be on a face
            start       (-1.001 -0.05 0.0011);
            end         (-1.001 -0.05 1.0011);
            nPoints     20;
        }
    }
2017-04-20 09:14:48 +01:00
79a050573b tutorials/multiphase: Removed unnecessary specification of name and dimensions for transport properties 2017-03-31 17:11:30 +01:00
cf0b6126d0 surfaceTensionModels: New class hierarchy for run-time selectable surface tension models
These models have been particularly designed for use in the VoF solvers, both
incompressible and compressible.  Currently constant and temperature dependent
surface tension models are provided but it easy to write models in which the
surface tension is evaluated from any fields held by the mesh database.
2017-03-31 14:32:38 +01:00
0ba6179f23 tutorials: Updated pcorr settings in fvSolution to provide pcorrFinal if required 2017-03-07 11:48:20 +00:00
ad92287afc Multi-phase solvers: Improved handling of inflow/outflow BCs in MULES
Avoids slight phase-fraction unboundedness at entertainment BCs and improved
robustness.

Additionally the phase-fractions in the multi-phase (rather than two-phase)
solvers are adjusted to avoid the slow growth of inconsistency ("drift") caused
by solving for all of the phase-fractions rather than deriving one from the
others.
2017-01-17 22:43:47 +00:00
07ae9b67cc totalPressureFvPatchScalarField, uniformTotalPressureFvPatchScalarField: simplified and rationalized
The modes of operation are set by the dimensions of the pressure field
    to which this boundary condition is applied, the \c psi entry and the value
    of \c gamma:
    \table
        Mode                    | dimensions | psi   | gamma
        incompressible subsonic | p/rho      |       |
        compressible subsonic   | p          | none  |
        compressible transonic  | p          | psi   | 1
        compressible supersonic | p          | psi   | > 1
    \endtable

    For most applications the totalPressure boundary condition now only
    requires p0 to be specified e.g.
    outlet
    {
        type            totalPressure;
        p0              uniform 1e5;
    }
2016-06-16 12:21:34 +01:00
e22c65dd8e Standardized the selection of required and optional fields in BCs, fvOptions, functionObjects etc.
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry.  Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':

        Property     | Description             | Required    | Default value
        U            | velocity field name     | no          | U
        phi          | flux field name         | no          | phi
        .
        .
        .

However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.

        Property     | Description             | Required    | Default value
        pName        | pressure field name     | no          | p
        UName        | velocity field name     | no          | U

This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance.  In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.
2016-05-21 20:28:20 +01:00
8cdd590333 tutorials: Renamed .org -> .orig
See http://www.openfoam.org/mantisbt/view.php?id=2076
  - .org is the file extension for emacs org-mode as well
  - .orig is more to the point (.org isn't always recognized as "original")
  - .original is too long, although more consistent with the convention
    of source code file naming

Update script contributed by Bruno Santos
2016-04-30 21:53:50 +01:00
fa0656c358 scripts: Reformat with consistent section separators 2016-02-15 18:30:24 +00:00
4f38542d44 tutorials: Simplified the Allrun and Allclean scripts 2016-02-14 18:32:34 +00:00
28006ee0a5 tutorials and templates: Updated wall BC for velocity to noSlip 2016-02-09 20:08:34 +00:00
20204cb468 bin/tools/RunFunctions: runParallel now obtains the number of processors from numberOfSubdomains
in decomposeParDict.

This default number of processors may be overridden by the new "-np"
option to runParallel which must be specified before the application
name e.g.:

runParallel -np 4 pisoFoam
2016-01-27 14:19:25 +00:00
d0e45416e0 tutorials: Removed unnecessary "boundary" files 2015-11-13 20:05:37 +00:00
2b1ee6b497 tutorials: Removed unnecessary spaces between parentheses and values in vectors 2015-07-21 20:55:44 +01:00
ecee2d275e Input of dimensionedScalars: update read-construction of dimensionedScalar in applications
so that the specification of the name and dimensions are optional in property dictionaries.

Update tutorials so that the name of the dimensionedScalar property is
no longer duplicated but optional dimensions are still provided and are
checked on read.
2015-07-20 22:52:53 +01:00
dc0523643f fluxRequired: Added setFluxRequired function to fvSchemes class
Added calls to setFluxRequired for p, p_rgh etc. in all solvers which
avoids the need to add fluxRequired entries in fvSchemes dictionaries.
2015-07-15 21:57:16 +01:00
2b9a2adf8c MRF: Separate MRF from fvOptions
fvOptions does not have the appropriate structure to support MRF as it
is based on option selection by user-specified fields whereas MRF MUST
be applied to all velocity fields in the particular solver.  A
consequence of the particular design choices in fvOptions made it
difficult to support MRF for multiphase and it is easier to support
frame-related and field related options separately.

Currently the MRF functionality provided supports only rotations but
the structure will be generalized to support other frame motions
including linear acceleration, SRF rotation and 6DoF which will be
run-time selectable.
2015-05-29 23:35:43 +01:00
3a3c29b284 blockMesh: Change default location of blockMeshDict from constant/polyMesh to system
For multi-region cases the default location of blockMeshDict is now system/<region name>

If the blockMeshDict is not found in system then the constant directory
is also checked providing backward-compatibility
2015-04-24 22:29:57 +01:00
5d3bb28994 tutorials: remove unnecessary under-relax fields entry 2015-02-22 16:52:21 +00:00
93732c8af4 Updated the whole of OpenFOAM to use the new templated TurbulenceModels library
The old separate incompressible and compressible libraries have been removed.

Most of the commonly used RANS and LES models have been upgraded to the
new framework but there are a few missing which will be added over the
next few days, in particular the realizable k-epsilon model.  Some of
the less common incompressible RANS models have been introduced into the
new library instantiated for incompressible flow only.  If they prove to
be generally useful they can be templated for compressible and
multiphase application.

The Spalart-Allmaras DDES and IDDES models have been thoroughly
debugged, removing serious errors concerning the use of S rather than
Omega.

The compressible instances of the models have been augmented by a simple
backward-compatible eddyDiffusivity model for thermal transport based on
alphat and alphaEff.  This will be replaced with a separate run-time
selectable thermal transport model framework in a few weeks.

For simplicity and ease of maintenance and further development the
turbulent transport and wall modeling is based on nut/nuEff rather than
mut/muEff for compressible models so that all forms of turbulence models
can use the same wall-functions and other BCs.

All turbulence model selection made in the constant/turbulenceProperties
dictionary with RAS and LES as sub-dictionaries rather than in separate
files which added huge complexity for multiphase.

All tutorials have been updated so study the changes and update your own
cases by comparison with similar cases provided.

Sorry for the inconvenience in the break in backward-compatibility but
this update to the turbulence modeling is an essential step in the
future of OpenFOAM to allow more models to be added and maintained for a
wider range of cases and physics.  Over the next weeks and months more
turbulence models will be added of single and multiphase flow, more
additional sub-models and further development and testing of existing
models.  I hope this brings benefits to all OpenFOAM users.

Henry G. Weller
2015-01-21 19:21:39 +00:00
195c566562 Minor change to comment 2014-12-14 21:50:14 +00:00
446e5777f0 Add the OpenFOAM source tree 2014-12-10 22:40:10 +00:00