ENH: Updated header documentation

This commit is contained in:
andy
2013-11-21 15:10:44 +00:00
parent 6544abe389
commit c00c3456e2

View File

@ -22,7 +22,7 @@ License
along with OpenFOAM. If not, see <http://www.gnu.org/licenses/>. along with OpenFOAM. If not, see <http://www.gnu.org/licenses/>.
Class Class
externalWallHeatFluxTemperatureFvPatchScalarField Foam::externalWallHeatFluxTemperatureFvPatchScalarField
Group Group
grpThermoBoundaryConditions grpWallBoundaryConditions grpThermoBoundaryConditions grpWallBoundaryConditions
@ -34,34 +34,50 @@ Description
fixed heat transfer coefficient mode. fixed heat transfer coefficient mode.
The condition can operate in two modes: The condition can operate in two modes:
\li fixed heat transfer coefficient: supply h and Ta - fixed heat transfer coefficient: supply h and Ta
\li fixed heat flux: supply q - fixed heat flux: supply q
where where:
\var h = heat transfer coefficient [W/m2/K] \vartable
\var Ta = ambient temperature [K] h | heat transfer coefficient [W/m2/K]
\var q = heat flux [W/m2] Ta | ambient temperature [K]
q | heat flux [W/m2]
\endvartable
The thermal conductivity, \c kappa, can either be retrieved from the The thermal conductivity, \c kappa, can either be retrieved from the
mesh database using the \c lookup option, or from a \c solidThermo mesh database using the \c lookup option, or from a \c solidThermo
thermophysical package. thermophysical package.
\heading Patch usage
\table
Property | Description | Required | Default value
kappa | thermal conductivity option | yes |
q | heat flux [W/m2] | yes* |
Ta | ambient temperature [K] | yes* |
h | heat transfer coefficient [W/m/K] | yes*|
thicknessLayers | list of thicknesses per layer [m] | yes |
kappaLayers | list of thermal conductivites per layer [W/m/K] | yes |
kappaName | name of thermal conductivity field | yes |
\endtable
Example of the boundary condition specification: Example of the boundary condition specification:
\verbatim \verbatim
myPatch myPatch
{ {
type externalWallHeatFluxTemperature; type externalWallHeatFluxTemperature;
kappa fluidThermo; // fluidThermo, solidThermo or kappa fluidThermo; // fluidThermo, solidThermo or
// lookup // lookup
q uniform 1000; // heat flux / [W/m2] q uniform 1000; // heat flux / [W/m2]
Ta uniform 300.0; // ambient temperature /[K] Ta uniform 300.0; // ambient temperature /[K]
h uniform 10.0; // heat transfer coeff /[W/Km2] h uniform 10.0; // heat transfer coeff /[W/Km2]
thicknessLayers (0.1 0.2 0.3 0.4); // thickness of layer [m] thicknessLayers (0.1 0.2 0.3 0.4); // thickness of layer [m]
kappaLayers (1 2 3 4) // thermal conductivity of kappaLayers (1 2 3 4) // thermal conductivity of
// layer [W/m/K] // layer [W/m/K]
value uniform 300.0; // initial temperature / [K] value uniform 300.0; // initial temperature / [K]
kappaName none; kappaName none;
} }
\endverbatim \endverbatim