- use the dictionary 'get' methods instead of readScalar for
additional checking
Unchecked: readScalar(dict.lookup("key"));
Checked: dict.get<scalar>("key");
- In templated classes that also inherit from a dictionary, an additional
'template' keyword will be required. Eg,
this->coeffsDict().template get<scalar>("key");
For this common use case, the predefined getXXX shortcuts may be
useful. Eg,
this->coeffsDict().getScalar("key");
- instead of dict.lookup(name) >> val;
can use dict.readEntry(name, val);
for checking of input token sizes.
This helps catch certain types of input errors:
{
key1 ; // <- Missing value
key2 1234 // <- Missing ';' terminator
key3 val;
}
STYLE: readIfPresent() instead of 'if found ...' in a few more places.
- when constructing dimensioned fields that are to be zero-initialized,
it is preferrable to use a form such as
dimensionedScalar(dims, Zero)
dimensionedVector(dims, Zero)
rather than
dimensionedScalar("0", dims, 0)
dimensionedVector("zero", dims, vector::zero)
This reduces clutter and also avoids any suggestion that the name of
the dimensioned quantity has any influence on the field's name.
An even shorter version is possible. Eg,
dimensionedScalar(dims)
but reduces the clarity of meaning.
- NB: UniformDimensionedField is an exception to these style changes
since it does use the name of the dimensioned type (instead of the
regIOobject).
The combustion and chemistry models no longer select and own the
thermodynamic model; they hold a reference instead. The construction of
the combustion and chemistry models has been changed to require a
reference to the thermodyanmics, rather than the mesh and a phase name.
At the solver-level the thermo, turbulence and combustion models are now
selected in sequence. The cyclic dependency between the three models has
been resolved, and the raw-pointer based post-construction step for the
combustion model has been removed.
The old solver-level construction sequence (typically in createFields.H)
was as follows:
autoPtr<combustionModels::psiCombustionModel> combustion
(
combustionModels::psiCombustionModel::New(mesh)
);
psiReactionThermo& thermo = combustion->thermo();
// Create rho, U, phi, etc...
autoPtr<compressible::turbulenceModel> turbulence
(
compressible::turbulenceModel::New(rho, U, phi, thermo)
);
combustion->setTurbulence(*turbulence);
The new sequence is:
autoPtr<psiReactionThermo> thermo(psiReactionThermo::New(mesh));
// Create rho, U, phi, etc...
autoPtr<compressible::turbulenceModel> turbulence
(
compressible::turbulenceModel::New(rho, U, phi, *thermo)
);
autoPtr<combustionModels::psiCombustionModel> combustion
(
combustionModels::psiCombustionModel::New(*thermo, *turbulence)
);
ENH: combustionModel, chemistryModel: Simplified model selection
The combustion and chemistry model selection has been simplified so
that the user does not have to specify the form of the thermodynamics.
Examples of new combustion and chemistry entries are as follows:
In constant/combustionProperties:
combustionModel PaSR;
combustionModel FSD;
In constant/chemistryProperties:
chemistryType
{
solver ode;
method TDAC;
}
All the angle bracket parts of the model names (e.g.,
<psiThermoCombustion,gasHThermoPhysics>) have been removed as well as
the chemistryThermo entry.
The changes are mostly backward compatible. Only support for the
angle bracket form of chemistry solver names has been removed. Warnings
will print if some of the old entries are used, as the parts relating to
thermodynamics are now ignored.
ENH: combustionModel, chemistryModel: Simplified model selection
Updated all tutorials to the new format
STYLE: combustionModel: Namespace changes
Wrapped combustion model make macros in the Foam namespace and removed
combustion model namespace from the base classes. This fixes a namespace
specialisation bug in gcc 4.8. It is also somewhat less verbose in the
solvers.
This resolves bug report https://bugs.openfoam.org/view.php?id=2787
ENH: combustionModels: Default to the "none" model
When the constant/combustionProperties dictionary is missing, the solver
will now default to the "none" model. This is consistent with how
radiation models are selected.
"pos" now returns 1 if the argument is greater than 0, otherwise it returns 0.
This is consistent with the common mathematical definition of the "pos" function:
https://en.wikipedia.org/wiki/Sign_(mathematics)
However the previous implementation in which 1 was also returned for a 0
argument is useful in many situations so the "pos0" has been added which returns
1 if the argument is greater or equal to 0. Additionally the "neg0" has been
added which returns 1 if if the argument is less than or equal to 0.
to avoid duplicate instantiation of the thermodynamics package.
The 'zoneCombustion' model is now selected in constant/combustionProperties by
either
combustionModel zoneCombustion<psiCombustionModel>;
or
combustionModel zoneCombustion<rhoCombustionModel>;
as appropriate.
Resolves bug-report http://bugs.openfoam.org/view.php?id=2354
in which the reactions are enabled only in the specified list of
cellZones. e.g. in constant/combustionProperties
combustionModel zoneCombustion<psiChemistryCombustion>;
active true;
zoneCombustionCoeffs
{
zones (catalyst);
}
and in constant/zoneCombustionProperties
combustionModel laminar<psiChemistryCombustion>;
active true;
laminarCoeffs
{}
and instanciating reactionThermos, Reactions, chemistrySolver
solidChemistrySolvers and readers.
chemkinReader uses the sensibleEnthalpy base of thermoType