Added the option '-subDict' to specify a sub-dictionary if multiple
replacement sets are present in the same file. This also provides
backward compatibility by setting '-subDict dictionaryReplacement'
In most boundary conditions, fvOptions etc. required and optional fields
to be looked-up from the objectRegistry are selected by setting the
keyword corresponding to the standard field name in the BC etc. to the
appropriate name in the objectRegistry. Usually a default is provided
with sets the field name to the keyword name, e.g. in the
totalPressureFvPatchScalarField the velocity is selected by setting the
keyword 'U' to the appropriate name which defaults to 'U':
Property | Description | Required | Default value
U | velocity field name | no | U
phi | flux field name | no | phi
.
.
.
However, in some BCs and functionObjects and many fvOptions another
convention is used in which the field name keyword is appended by 'Name'
e.g.
Property | Description | Required | Default value
pName | pressure field name | no | p
UName | velocity field name | no | U
This difference in convention is unnecessary and confusing, hinders code
and dictionary reuse and complicates code maintenance. In this commit
the appended 'Name' is removed from the field selection keywords
standardizing OpenFOAM on the first convention above.
This changes simplifies the specification of functionObjects in
controlDict and is consistent with the 'libs' option in controlDict to
load special solver libraries.
Support for the old 'functionObjectLibs' name is supported for backward compatibility.
- Avoids the need for the 'OutputFilterFunctionObject' wrapper
- Time-control for execution and writing is now provided by the
'timeControlFunctionObject' which instantiates the processing
'functionObject' and controls its operation.
- Alternative time-control functionObjects can now be written and
selected at run-time without the need to compile wrapped version of
EVERY existing functionObject which would have been required in the
old structure.
- The separation of 'execute' and 'write' functions is now formalized in the
'functionObject' base-class and all derived classes implement the
two functions.
- Unnecessary implementations of functions with appropriate defaults
in the 'functionObject' base-class have been removed reducing
clutter and simplifying implementation of new functionObjects.
- The 'coded' 'functionObject' has also been updated, simplified and tested.
- Further simplification is now possible by creating some general
intermediate classes derived from 'functionObject'.
See http://www.openfoam.org/mantisbt/view.php?id=2076
- .org is the file extension for emacs org-mode as well
- .orig is more to the point (.org isn't always recognized as "original")
- .original is too long, although more consistent with the convention
of source code file naming
Update script contributed by Bruno Santos
Also added the new prghTotalHydrostaticPressure p_rgh BC which uses the
hydrostatic pressure field as the reference state for the far-field
which provides much more accurate entrainment is large open domains
typical of many fire simulations.
The hydrostatic field solution is controlled by the optional entries in
the fvSolution.PIMPLE dictionary, e.g.
hydrostaticInitialization yes;
nHydrostaticCorrectors 5;
and the solver must also be specified for the hydrostatic p_rgh field
ph_rgh e.g.
ph_rgh
{
$p_rgh;
}
Suitable boundary conditions for ph_rgh cannot always be derived from
those for p_rgh and so the ph_rgh is read to provide them.
To avoid accuracy issues with IO, restart and post-processing the p_rgh
and ph_rgh the option to specify a suitable reference pressure is
provided via the optional pRef file in the constant directory, e.g.
dimensions [1 -1 -2 0 0 0 0];
value 101325;
which is used in the relationship between p_rgh and p:
p = p_rgh + rho*gh + pRef;
Note that if pRef is specified all pressure BC specifications in the
p_rgh and ph_rgh files are relative to the reference to avoid round-off
errors.
For examples of suitable BCs for p_rgh and ph_rgh for a range of
fireFoam cases please study the tutorials in
tutorials/combustion/fireFoam/les which have all been updated.
Henry G. Weller
CFD Direct Ltd.
RunFunctions: Added "isTest()" argument parsing function
tutorials: Updated Allrun scripts to propagate the "-test" option
tutorials: Removed the lower Alltest scripts and updated the Allrun to
use the "isTest()" function to handle test-specific operation
in decomposeParDict.
This default number of processors may be overridden by the new "-np"
option to runParallel which must be specified before the application
name e.g.:
runParallel -np 4 pisoFoam
Adding boundary file from our dev to incompressible/simpleFoam/airFoil2D
Adding missing boundaryRadiationProperties combustion/fireFoam/les/flameSpreadWaterSuppressionPanel