Updated objects
- corrected Peclet number for compressible cases
- propagated log flag and resultName across objects
New function objects
- new fluxSummary:
- calculates positive, negative, absolute and net flux across face
zones
- new runTimeControl
- abort the calculation when a user-defined metric is achieved.
Available options include:
- average value remains unchanged wrt a given threshold
- equation initial residual exceeds a threshold - useful to abort
diverging cases
- equation max iterations exceeds a threshold - useful to abort
diverging cases
- min/max of a function object value
- min time step exceeds a threshold - useful to abort diverging
cases
- new valueAverage:
- average singular values from other function objects, e.g. Cd, Cl and
Cm from the forceCoeffs function object
This had been used in functionObjects:
Info(log)<< "messages" << data << ....
in which it is not at all clear what the "log" argument does whereas
if (log) Info<< "messages" << data << ....
is totally clear and more efficient.
Previous behavior which may be useful for moving-mesh cases can be
selected using the optional entry:
writeVolume yes;
The initial volume is written in the log and data file header e.g.:
# Source : all
# Cells : 3829
# Volume : 9.943164e-01
Also added
sumMag | sum of component magnitudes
- readFields works seamlessly on-the-fly and as postprocessor
- new surfaceInterpolateFields to create interpolated field
- writeRegisteredObject only check upon writing, not upon startup
- add min,max to faceSource