in case of tmp misuse.
Simplified tmp reuse pattern in field algebra to use tmp copy and
assignment rather than the complex delayed call to 'ptr()'.
Removed support for unused non-const 'REF' storage of non-tmp objects due to C++
limitation in constructor overloading: if both tmp(T&) and tmp(const T&)
constructors are provided resolution is ambiguous.
The turbulence libraries have been upgraded and '-DCONST_TMP' option
specified in the 'options' file to switch to the new 'tmp' behavior.
This change requires that the de-reference operator '()' returns a
const-reference to the object stored irrespective of the const-ness of
object stored and the new member function 'ref()' is provided to return
an non-const reference to stored object which throws a fatal error if the
stored object is const.
In order to smooth the transition to this new safer 'tmp' the now
deprecated and unsafe non-const de-reference operator '()' is still
provided by default but may be switched-off with the compilation switch
'CONST_TMP'.
The main OpenFOAM library has already been upgraded and '-DCONST_TMP'
option specified in the 'options' file to switch to the new 'tmp'
behavior. The rest of OpenFOAM-dev will be upgraded over the following
few weeks.
Henry G. Weller
CFD Direct
To be used instead of zeroGradientFvPatchField for temporary fields for
which zero-gradient extrapolation is use to evaluate the boundary field
but avoiding fields derived from temporary field using field algebra
inheriting the zeroGradient boundary condition by the reuse of the
temporary field storage.
zeroGradientFvPatchField should not be used as the default patch field
for any temporary fields and should be avoided for non-temporary fields
except where it is clearly appropriate;
extrapolatedCalculatedFvPatchField and calculatedFvPatchField are
generally more suitable defaults depending on the manner in which the
boundary values are specified or evaluated.
The entire OpenFOAM-dev code-base has been updated following the above
recommendations.
Henry G. Weller
CFD Direct
The boundary conditions of HbyA are now constrained by the new "constrainHbyA"
function which applies the velocity boundary values for patches for which the
velocity cannot be modified by assignment and pressure extrapolation is
not specified via the new
"fixedFluxExtrapolatedPressureFvPatchScalarField".
The new function "constrainPressure" sets the pressure gradient
appropriately for "fixedFluxPressureFvPatchScalarField" and
"fixedFluxExtrapolatedPressureFvPatchScalarField" boundary conditions to
ensure the evaluated flux corresponds to the known velocity values at
the boundary.
The "fixedFluxPressureFvPatchScalarField" boundary condition operates
exactly as before, ensuring the correct flux at fixed-flux boundaries by
compensating for the body forces (gravity in particular) with the
pressure gradient.
The new "fixedFluxExtrapolatedPressureFvPatchScalarField" boundary
condition may be used for cases with or without body-forces to set the
pressure gradient to compensate not only for the body-force but also the
extrapolated "HbyA" which provides a second-order boundary condition for
pressure. This is useful for a range a problems including impinging
flow, extrapolated inlet conditions with body-forces or for highly
viscous flows, pressure-induced separation etc. To test this boundary
condition at walls in the motorBike tutorial case set
lowerWall
{
type fixedFluxExtrapolatedPressure;
}
motorBikeGroup
{
type fixedFluxExtrapolatedPressure;
}
Currently the new extrapolated pressure boundary condition is supported
for all incompressible and sub-sonic compressible solvers except those
providing implicit and tensorial porosity support. The approach will be
extended to cover these solvers and options in the future.
Note: the extrapolated pressure boundary condition is experimental and
requires further testing to assess the range of applicability,
stability, accuracy etc.
Henry G. Weller
CFD Direct Ltd.
Function1 is an abstract base-class of run-time selectable unary
functions which may be composed of other Function1's allowing the user
to specify complex functions of a single scalar variable, e.g. time.
The implementations need not be a simple or continuous functions;
interpolated tables and polynomials are also supported. In fact form of
mapping between a single scalar input and a single primitive type output
is supportable.
The primary application of Function1 is in time-varying boundary
conditions, it also used for other functions of time, e.g. injected mass
is spray simulations but is not limited to functions of time.
PV4FoamReaders: Updated to build with ParaView-5.0.0
paraFoam: Updated to load PV4FoamReaders for ParaView-5.0.0
Currently this is experimental but if it becomes clear that ParaView-4
and ParaView-5 are and will remain consistent with respect to readers
the plan is to rename
PV4 -> PV
or
PV4 -> PV45 if it is assumed that PV6 may need to be different.
Drag model for gas-liquid system of Tomiyama et al.
Reference:
"Drag coefficients of single bubbles under normal and microgravity
conditions"
Tomiyama, A., Kataoka, I., Zun, I., Sakaguchi, T.
JSME International Series B, Fluids and Thermal Engineering,
Vol. 41, 1998, pp. 472-479
Provided by Alberto Passalacq
It is better to declare the namespace of each function in the C file
rather than "open" the namespace as this may lead to inconsistencies
between the declaration in the H files and definition in the C file.
fvOptions are transferred to the database on construction using
fv::options::New which returns a reference. The same function can be
use for construction and lookup so that fvOptions are now entirely
demand-driven.
The abstract base-classes for fvOptions now reside in the finiteVolume
library simplifying compilation and linkage. The concrete
implementations of fvOptions are still in the single monolithic
fvOptions library but in the future this will be separated into smaller
libraries based on application area which may be linked at run-time in
the same manner as functionObjects.