The standard naming convention for heat flux is "q" and this is used for the conductive and convective heat fluxes is OpenFOAM. The use of "Qr" for radiative heat flux is an anomaly which causes confusion, particularly for boundary conditions in which "Q" is used to denote power in Watts. The name of the radiative heat flux has now been corrected to "qr" and all models, boundary conditions and tutorials updated.
72 lines
2.0 KiB
C++
72 lines
2.0 KiB
C++
/*--------------------------------*- C++ -*----------------------------------*\
|
|
| ========= | |
|
|
| \\ / F ield | OpenFOAM: The Open Source CFD Toolbox |
|
|
| \\ / O peration | Version: dev |
|
|
| \\ / A nd | Web: www.OpenFOAM.org |
|
|
| \\/ M anipulation | |
|
|
\*---------------------------------------------------------------------------*/
|
|
FoamFile
|
|
{
|
|
version 2.0;
|
|
format ascii;
|
|
class dictionary;
|
|
object changeDictionaryDict;
|
|
}
|
|
// * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * //
|
|
|
|
boundary
|
|
{
|
|
minZ
|
|
{
|
|
type patch;
|
|
}
|
|
maxZ
|
|
{
|
|
type patch;
|
|
}
|
|
}
|
|
|
|
T
|
|
{
|
|
internalField uniform 300;
|
|
|
|
boundaryField
|
|
{
|
|
".*"
|
|
{
|
|
type zeroGradient;
|
|
value uniform 300;
|
|
}
|
|
|
|
rightSolid_to_topAir
|
|
{
|
|
type compressible::turbulentTemperatureRadCoupledMixed;
|
|
Tnbr T;
|
|
kappaMethod solidThermo;
|
|
qrNbr qr;
|
|
qr none;
|
|
value uniform 300;
|
|
}
|
|
|
|
rightSolid_to_bottomAir
|
|
{
|
|
type compressible::turbulentTemperatureRadCoupledMixed;
|
|
Tnbr T;
|
|
kappaMethod solidThermo;
|
|
qrNbr qr;
|
|
qr none;
|
|
value uniform 300;
|
|
}
|
|
|
|
"rightSolid_to_.*"
|
|
{
|
|
type compressible::turbulentTemperatureCoupledBaffleMixed;
|
|
Tnbr T;
|
|
kappaMethod solidThermo;
|
|
value uniform 300;
|
|
}
|
|
}
|
|
}
|
|
|
|
// ************************************************************************* //
|