Corrected form of the Rosin-Rammler distribution taking into account the
varying number of particels per parces for for fixed-mass parcels. This
distribution should be used when
\verbatim
parcelBasisType mass;
\endverbatim
See equation 10 in reference:
\verbatim
Yoon, S. S., Hewson, J. C., DesJardin, P. E., Glaze, D. J.,
Black, A. R., & Skaggs, R. R. (2004).
Numerical modeling and experimental measurements of a high speed
solid-cone water spray for use in fire suppression applications.
International Journal of Multiphase Flow, 30(11), 1369-1388.
\endverbatim