Andrew Heather c6433e32c2 ENH: Extended the effectiveness heat exchanger source to enable target
heat rejection

The new optional entry targetQdot can be used to specify a target heat
rejection.  This is additionally controlled using the
targetQdotCalcInterval  and targetQdotRelax entries which default to
values of 5 and 0.5, respectively.