@ -420,6 +420,48 @@ different arguments.
|
||||
This error message might also require a close look at other LAMMPS input files
|
||||
that are read in by the input script, such as data files or restart files.
|
||||
|
||||
.. _err0021:
|
||||
|
||||
Energy was not tallied on needed timestep (also virial, per-atom energy, per-atom virial)
|
||||
-----------------------------------------------------------------------------------------
|
||||
|
||||
This error is generated when LAMMPS attempts to access an out-of-date
|
||||
or non-existent energy, pressure, or virial.
|
||||
For efficiency reasons,
|
||||
LAMMPS does *not* calculate these quantities when the forces are calculated
|
||||
on every timestep or iteration. Global quantities are only calculated
|
||||
when they are needed for :doc:`thermo <thermo_style>` output (at the beginning, end,
|
||||
and at regular intervals specified by the :doc:`thermo <thermo>` command). Similarly,
|
||||
per-atom quantities are only calculated if they are needed to write per-atom
|
||||
energy or virial to a dump file.
|
||||
This system works fine for simple input scripts.
|
||||
However, the many user-specified `variable`, `fix`, and `compute` commands
|
||||
that LAMMPS provides make it difficult to anticipate when a quantity will
|
||||
be requested. In some use cases, LAMMPS will figure out that a quantity is needed
|
||||
and arrange for it to be calculated on that timestep e.g. if it is requested by
|
||||
:doc:`fix ave/time <fix_ave_time>` or similar commands.
|
||||
If that fails, it can be detected by a mismatch
|
||||
between the current timestep and when a quantity was last calculated,
|
||||
in which case an error message of this type is generated.
|
||||
|
||||
The most common cause of this type of error is requesting a quantity before
|
||||
the start of the simulation.
|
||||
|
||||
.. code-block:: LAMMPS
|
||||
|
||||
# run 0 post no # this will fix the error
|
||||
variable e equal pe # requesting energy compute
|
||||
print "Potential energy = $e" # this will generate the error
|
||||
run 1000 # start of simulation
|
||||
|
||||
This situation can be avoided by adding in a "run 0" command, as explained in
|
||||
more detail in the "Variable Accuracy" section of the
|
||||
:doc:`variable <variable>` doc page.
|
||||
|
||||
Another cause is requesting a quantity on a timestep that is not
|
||||
a thermo or dump output timestep. This can often be
|
||||
remedied by increasing the frequency of thermo or dump output.
|
||||
|
||||
.. _err0024:
|
||||
|
||||
Molecule topology/atom exceeds system topology/atom
|
||||
|
||||
Reference in New Issue