doc page for write_data
This commit is contained in:
@ -19,6 +19,7 @@ Syntax
|
||||
*nocoeff* = do not write out force field info
|
||||
*nofix* = do not write out extra sections read by fixes
|
||||
*nolabelmap* = do not write out type labels
|
||||
*triclinic/general = write data file in general triclinic format
|
||||
*types* value = *numeric* or *labels*
|
||||
*pair* value = *ii* or *ij*
|
||||
*ii* = write one line of pair coefficient info per atom type
|
||||
@ -31,6 +32,7 @@ Examples
|
||||
|
||||
write_data data.polymer
|
||||
write_data data.*
|
||||
write_data data.solid triclinic/general
|
||||
|
||||
Description
|
||||
"""""""""""
|
||||
@ -85,10 +87,11 @@ using the :doc:`-r command-line switch <Run_options>`.
|
||||
:doc:`fixes <fix>` are stored. :doc:`Binary restart files <read_restart>`
|
||||
store more information.
|
||||
|
||||
Bond interactions (angle, etc) that have been turned off by the :doc:`fix shake <fix_shake>` or :doc:`delete_bonds <delete_bonds>` command will
|
||||
be written to a data file as if they are turned on. This means they
|
||||
will need to be turned off again in a new run after the data file is
|
||||
read.
|
||||
Bond interactions (angle, etc) that have been turned off by the
|
||||
:doc:`fix shake <fix_shake>` or :doc:`delete_bonds <delete_bonds>`
|
||||
command will be written to a data file as if they are turned on. This
|
||||
means they will need to be turned off again in a new run after the
|
||||
data file is read.
|
||||
|
||||
Bonds that are broken (e.g. by a bond-breaking potential) are not
|
||||
written to the data file. Thus these bonds will not exist when the
|
||||
@ -122,6 +125,23 @@ not written to the data file. By default, they are written if they
|
||||
exist. A type label must be defined for every numeric type (within a
|
||||
given type-kind) to be written to the data file.
|
||||
|
||||
Use of the *triclinic/general* keyword will output a data file which
|
||||
specifies a general triclinic simulation box as well as per-atom
|
||||
quantities consistent with the general triclinic box. The latter
|
||||
means that per-atom vectors, such as velocities and dipole moments
|
||||
will be oriented conistent with the 3d rotation implied by the general
|
||||
triclinic box (relative to the associated restricted triclinic box).
|
||||
|
||||
This option can only be requested if the simulation box was initially
|
||||
defined to be general triclinic. If if was and the
|
||||
*triclinic/general* keyword is not used, then the data file will
|
||||
specify a restricted triclinic box, since that is the internal format
|
||||
LAMMPS uses for both general and restricited triclinic simulations.
|
||||
See the :doc:`Howto triclinic <Howto_triclinic>` doc page for more
|
||||
explanation of how general triclinic simulation boxes are supported by
|
||||
LAMMPS. And see the :doc:`read_data <read_data>` doc page for details
|
||||
of how the format is altered for general triclinic data files.
|
||||
|
||||
The *types* keyword determines how atom types, bond types, angle
|
||||
types, etc are written into these data file sections: Atoms, Bonds,
|
||||
Angles, etc. The default is the *numeric* setting, even if type label
|
||||
|
||||