- changed the sectorCoeffs keyword to 'point' from 'axisPt'
for more similarity with other dictionaries.
Continue to accept 'axisPt' for compatibility.
- use the dictionary 'get' methods instead of readScalar for
additional checking
Unchecked: readScalar(dict.lookup("key"));
Checked: dict.get<scalar>("key");
- In templated classes that also inherit from a dictionary, an additional
'template' keyword will be required. Eg,
this->coeffsDict().template get<scalar>("key");
For this common use case, the predefined getXXX shortcuts may be
useful. Eg,
this->coeffsDict().getScalar("key");
- Since 'bool' and 'Switch' use the _identical_ input mechanism
(ie, both accept true/false, on/off, yes/no, none, 1/0), the main
reason to prefer one or the other is the output.
The output for Switch is as text (eg, "true"), whereas for bool
it is label (0 or 1). If the output is required for a dictionary,
Switch may be appropriate. If the output is not required, or is only
used for Pstream exchange, bool can be more appropriate.
except turbulence and lagrangian which will also be updated shortly.
For example in the nonNewtonianIcoFoam offsetCylinder tutorial the viscosity
model coefficients may be specified in the corresponding "<type>Coeffs"
sub-dictionary:
transportModel CrossPowerLaw;
CrossPowerLawCoeffs
{
nu0 [0 2 -1 0 0 0 0] 0.01;
nuInf [0 2 -1 0 0 0 0] 10;
m [0 0 1 0 0 0 0] 0.4;
n [0 0 0 0 0 0 0] 3;
}
BirdCarreauCoeffs
{
nu0 [0 2 -1 0 0 0 0] 1e-06;
nuInf [0 2 -1 0 0 0 0] 1e-06;
k [0 0 1 0 0 0 0] 0;
n [0 0 0 0 0 0 0] 1;
}
which allows a quick change between models, or using the simpler
transportModel CrossPowerLaw;
nu0 [0 2 -1 0 0 0 0] 0.01;
nuInf [0 2 -1 0 0 0 0] 10;
m [0 0 1 0 0 0 0] 0.4;
n [0 0 0 0 0 0 0] 3;
if quick switching between models is not required.
To support this more convenient parameter specification the inconsistent
specification of seedSampleSet in the streamLine and wallBoundedStreamLine
functionObjects had to be corrected from
// Seeding method.
seedSampleSet uniform; //cloud; //triSurfaceMeshPointSet;
uniformCoeffs
{
type uniform;
axis x; //distance;
// Note: tracks slightly offset so as not to be on a face
start (-1.001 -0.05 0.0011);
end (-1.001 -0.05 1.0011);
nPoints 20;
}
to the simpler
// Seeding method.
seedSampleSet
{
type uniform;
axis x; //distance;
// Note: tracks slightly offset so as not to be on a face
start (-1.001 -0.05 0.0011);
end (-1.001 -0.05 1.0011);
nPoints 20;
}
which also support the "<type>Coeffs" form
// Seeding method.
seedSampleSet
{
type uniform;
uniformCoeffs
{
axis x; //distance;
// Note: tracks slightly offset so as not to be on a face
start (-1.001 -0.05 0.0011);
end (-1.001 -0.05 1.0011);
nPoints 20;
}
}
The deprecated non-const tmp functionality is now on the compiler switch
NON_CONST_TMP which can be enabled by adding -DNON_CONST_TMP to EXE_INC
in the Make/options file. However, it is recommended to upgrade all
code to the new safer tmp by using the '.ref()' member function rather
than the non-const '()' dereference operator when non-const access to
the temporary object is required.
Please report any problems on Mantis.
Henry G. Weller
CFD Direct.
Function1 is an abstract base-class of run-time selectable unary
functions which may be composed of other Function1's allowing the user
to specify complex functions of a single scalar variable, e.g. time.
The implementations need not be a simple or continuous functions;
interpolated tables and polynomials are also supported. In fact form of
mapping between a single scalar input and a single primitive type output
is supportable.
The primary application of Function1 is in time-varying boundary
conditions, it also used for other functions of time, e.g. injected mass
is spray simulations but is not limited to functions of time.
1) Modification to extrudeToRegionMesh to use extrudeModel point distribution function
2) Addition of firstCellThickness option to linearNormal extrude model