- previously introduced `getOrDefault` as a dictionary _get_ method,
now complete the transition and use it everywhere instead of
`lookupOrDefault`. This avoids mixed usage of the two methods that
are identical in behaviour, makes for shorter names, and promotes
the distinction between "lookup" access (ie, return a token stream,
locate and return an entry) and "get" access (ie, the above with
conversion to concrete types such as scalar, label etc).
Modified revert of commit 6c6f777bd5.
- The "alphaContactAngleFvPatchScalarField" occurs in several
places in the code base:
- as abstract class for two-phase properties
- in various multiphase solvers
To resolve potential linking conflicts, renamed the abstract class
as "alphaContactAngleTwoPhaseFvPatchScalarField" instead.
This permits potential linking of two-phase and multi-phase
libraries without symbol conflicts and has no effect on concrete
uses of two-phase alphaContactAngle boudary conditions.
- deprecate dimensionedType constructors using an Istream in favour of
versions accepting a keyword and a dictionary.
Dictionary entries are almost the exclusive means of read
constructing a dimensionedType. By construct from the dictionary
entry instead of doing a lookup() first, we can detect possible
input errors such as too many tokens as a result of a input syntax
error.
Constructing a dimensionedType from a dictionary entry now has
two forms.
1. dimensionedType(key, dims, dict);
This is the constructor that will normally be used.
It accepts entries with optional leading names and/or
dimensions. If the entry contains dimensions, they are
verified against the expected dimensions and an IOError is
raised if they do not correspond. On conclusion, checks the
token stream for any trailing rubbish.
2. dimensionedType(key, dict);
This constructor is used less frequently.
Similar to the previous description, except that it is initially
dimensionless. If entry contains dimensions, they are used
without further verification. The constructor also includes a
token stream check.
This constructor is useful when the dimensions are entirely
defined from the dictionary input, but also when handling
transition code where the input dimensions are not obvious from
the source.
This constructor can also be handy when obtaining values from
a dictionary without needing to worry about the input dimensions.
For example,
Info<< "rho: " << dimensionedScalar("rho", dict).value() << nl;
This will accept a large range of inputs without hassle.
ENH: consistent handling of dimensionedType for inputs (#1083)
BUG: incorrect Omega dimensions (fixes#2084)
- when constructing dimensioned fields that are to be zero-initialized,
it is preferrable to use a form such as
dimensionedScalar(dims, Zero)
dimensionedVector(dims, Zero)
rather than
dimensionedScalar("0", dims, 0)
dimensionedVector("zero", dims, vector::zero)
This reduces clutter and also avoids any suggestion that the name of
the dimensioned quantity has any influence on the field's name.
An even shorter version is possible. Eg,
dimensionedScalar(dims)
but reduces the clarity of meaning.
- NB: UniformDimensionedField is an exception to these style changes
since it does use the name of the dimensioned type (instead of the
regIOobject).
"pos" now returns 1 if the argument is greater than 0, otherwise it returns 0.
This is consistent with the common mathematical definition of the "pos" function:
https://en.wikipedia.org/wiki/Sign_(mathematics)
However the previous implementation in which 1 was also returned for a 0
argument is useful in many situations so the "pos0" has been added which returns
1 if the argument is greater or equal to 0. Additionally the "neg0" has been
added which returns 1 if if the argument is less than or equal to 0.
These models have been particularly designed for use in the VoF solvers, both
incompressible and compressible. Currently constant and temperature dependent
surface tension models are provided but it easy to write models in which the
surface tension is evaluated from any fields held by the mesh database.
When the GeometricBoundaryField template class was originally written it
was a separate class in the Foam namespace rather than a sub-class of
GeometricField as it is now. Without loss of clarity and simplifying
code which access the boundary field of GeometricFields it is better
that GeometricBoundaryField be renamed Boundary for consistency with the
new naming convention for the type of the dimensioned internal field:
Internal, see commit 4a57b9be2e
This is a very simple text substitution change which can be applied to
any code which compiles with the OpenFOAM-dev libraries.
The deprecated non-const tmp functionality is now on the compiler switch
NON_CONST_TMP which can be enabled by adding -DNON_CONST_TMP to EXE_INC
in the Make/options file. However, it is recommended to upgrade all
code to the new safer tmp by using the '.ref()' member function rather
than the non-const '()' dereference operator when non-const access to
the temporary object is required.
Please report any problems on Mantis.
Henry G. Weller
CFD Direct.
so that the specification of the name and dimensions are optional in property dictionaries.
Update tutorials so that the name of the dimensionedScalar property is
no longer duplicated but optional dimensions are still provided and are
checked on read.
Note that currently when transportProperties is changed sigma is re-read
from this dictionary but cAlpha is read from fvSolution but cAlpha is
not re-read when fvSolution is changed but transportProperties is not
touched. To avoid this problem cAlpha would need to be moved to the
transportProperties dictionary which is not ideal or moved out of the
interfaceProperties class back to the top-level solver.
Resolves bug-report http://www.openfoam.org/mantisbt/view.php?id=1657
MULES: Add support for explicit correction
interPhaseChangeFoam: Add option for explicit MULES or as correction to an upwind solution
Deprecate implicit form of MULES