The standard naming convention for heat flux is "q" and this is used for the
conductive and convective heat fluxes is OpenFOAM. The use of "Qr" for
radiative heat flux is an anomaly which causes confusion, particularly for
boundary conditions in which "Q" is used to denote power in Watts. The name of
the radiative heat flux has now been corrected to "qr" and all models, boundary
conditions and tutorials updated.
using a run-time selectable preconditioner
References:
Van der Vorst, H. A. (1992).
Bi-CGSTAB: A fast and smoothly converging variant of Bi-CG
for the solution of nonsymmetric linear systems.
SIAM Journal on scientific and Statistical Computing, 13(2), 631-644.
Barrett, R., Berry, M. W., Chan, T. F., Demmel, J., Donato, J.,
Dongarra, J., Eijkhout, V., Pozo, R., Romine, C. & Van der Vorst, H.
(1994).
Templates for the solution of linear systems:
building blocks for iterative methods
(Vol. 43). Siam.
See also: https://en.wikipedia.org/wiki/Biconjugate_gradient_stabilized_method
Tests have shown that PBiCGStab with the DILU preconditioner is more
robust, reliable and shows faster convergence (~2x) than PBiCG with
DILU, in particular in parallel where PBiCG occasionally diverges.
This remarkable improvement over PBiCG prompted the update of all
tutorial cases currently using PBiCG to use PBiCGStab instead. If any
issues arise with this update please report on Mantis: http://bugs.openfoam.org